5,829 research outputs found

    Study of certain tether safety issues. Continuation of investigation of electrodynamic stabilization and control of long orbiting tethers, volume 1

    Get PDF
    The behavior of long tethers (10-100 km) in space are addressed under two failure situations with potential safety impact: instantaneous jamming of the reel controlling the tether during deployment and cutting of the tether due to a meteor strike or other similar phenomena. Dual and multiple mass point models were used in the SAO SKYHOOK program to determine this behavior. The results of the program runs were verified analytically or by comparison with previously verified results. The study included the effects of tether damping and air drag where appropriate. Most runs were done with the tether system undamped since we believe this best represents the true behavior of the tether. Means for controlling undesirable behavior of the tether, such as viscous dampers in the subsatellite, were also studied

    Ultra High Energy Neutrino-Relic Neutrino Interactions In Dark Halos to Solve Infrared-Tev And GZK Cut-Off

    Get PDF
    Ultra High Energy Neutrino scattering on Relic Light Neutrinos in Dark Galactic or Local Group lead to Z and WW,ZZ showering: the nucleon component of the shower may overcome the GZK cut-off while the electro-magnetic tail at TeVs up to EeVs energy may solve the Infrared-TeV cut-off in a natural way. Different Gamma TeV puzzles may find a solution within this scenario: new predictions on UHECR spectra in future data are derived.Comment: 4 pages, 3 figures, 2 tables ICRC 2001 HE 3.6 Dark Matter - German

    Orbital transfer and release of tethered payloads. Continuation of investigation of electrodynamic stabilization and control of long orbiting tethers Martinez-Sanchez, Manuel

    Get PDF
    The effect of reeling operations on the orbital altitude of the tether system and the development of control laws to minimize tether rebound upon payload release were studied. The use of the tether for LEO/GEO payload orbital transfer was also investigated. It was concluded that (1) reeling operations can contribute a significant amount of energy to the orbit of the system and should be considered in orbit calculations and predictions, (2) deployment of payloads, even very large payloads, using tethers is a practical and fully stable operation, (3) tether augmented LEO/GEO transfer operations yield useful payload gains under the practical constraint of fixed size OTV's, and (4) orbit to orbit satellite retrieval is limited by useful revisit times to orbital inclinations of less than forty-five degrees

    Satellite To Satellite Doppler Tracking (SSDT) for mapping of the Earth's gravity field

    Get PDF
    Two SSDT schemes were evaluated: a standard, low-low, SSDT configuration, which both satellites are in basically the same low altitude nearly circular orbit and the pair is characterized by small angular separation; and a more general configuration in which the two satellites are in arbitrary orbits, so that different configurations can be comparatively analyed. The standard low-low SSDT configuration is capable of recovering 1 deg X 1 deg surface anomalies with a strength as low as 1 milligal, located on the projected satellite path, when observing from a height as large as 300 km. The Colombo scheme provides an important complement of SSDT observations, inasmuch as it is sensitive to radial velocity components, while keeping at the same performance level both measuring sensitivity and measurement resolution

    A Novel Ultrasound-based Measure of the Liver among Diabetes Mellitus Type II Patients

    Get PDF
    Diabetes mellitus type II (DM II) or adult onset diabetes is due to the inefficient use of insulin, which affects various organs and tissues. Patients with DM II are at risk of suffering non-alcoholic fatty liver disease (NAFLD) that can later develop into more life threating forms such as hepatomegaly, cirrhosis or liver cancer. Following the logic of the non-inferiority trial test, we aim to establish a more accurate anatomical measure of the right liver lobe (RLL) to facilitate close monitoring of liver size with ultrasound (US). We hypothesize that US is not unacceptably worse than computed tomography (CT) or magnetic resonance imaging (MRI) to accurately and reliably measure the size of the RLL when the measure is taken in the midaxillary line and craniocaudal plane (MAL-CC). Therefore, the objective of this study is to conduct a non-inferiority trial to test our novel MAL-CC measure. To meet this aim, US measure of the RLL was taken from DM II (n=7) and non-DM II (n=5) patients, whom were recruited from 2 endocrinology clinics at SoM-UPR. Preliminary data shows that MAL-CC measure of the RLL from non-DM II patients is 13.99 + 2.53 cm whereas the same measurement among DM II patients is 15.25 + 3.25 cm (Mann-Whitney U test, p= 0.42). It is concluded that there is a non-significant trend for large RLL sizes among DM II patients. Future work aims to increase sample size and to validate our novel measurement with MRI

    Measurement of the Z/γ∗ forward-backward asymmetry in muon pairs with the ATLAS experiment at the LHC

    Get PDF
    A study on muon pairs produced through an intermediate Z/γ ∗, in pp collisions at the LHC, at a center-of-mass energy of 7TeV, is presented. After a selection aimed at enhancing the contribution from Z boson decay, the topology of the events is analyzed, and the forward-backward asymmetry is measured. The result is then used to test a method to measure the effective weak mixing angle sin2 θeff W . This note summarizes the results obtained with 2011 data collected by the ATLAS experiment at the LHC, corresponding to an integrated luminosity of 4.8 fb−1

    Apollo-Soyuz Doppler-tracking experiment MA-089

    Get PDF
    The Doppler tracking experiment was designed to test the feasibility of improved mapping of the earth's gravity field by the low-low satellite-to-satellite tracking method and to observe variations in the electron density of the ionosphere between the two spacecraft. Data were taken between 1:01 and 14:37 GMT on July 24, 1975. Baseline data taken earlier, while the docking module was still attached to the command and service module, indicated that the equipment operated satisfactorily. The ionospheric data contained in the difference between the Doppler signals at the two frequencies are of excellent quality, resulting in valuable satellite-to-satellite observations, never made before, of wave phenomena in the ionosphere. The gravity data were corrupted by an unexpectedly high noise level of as-yet-undetermined origin, with periods greater than 150 seconds, that prevented unambiguous identification of gravity-anomaly signatures

    Maxillary nerve block: A comparison between the greater palatine canal and high tuberosity approaches.

    Get PDF
    Aim: Analgesia and anxiolysis during dental procedures are important for dental care and patient compliance. This study aims to compare two classical maxillary nerve block (MNB) techniques: the greater palatine canal (GPC) and the high tuberosity (HT) approaches, seldom used in routine dental practice. Methods: The study was conducted on 30 patients, scheduled for sinus lift surgery, who were randomly divided into 2 groups: the GPC approach to the MNB was used in 15 and the HT one in the other 15 patients. Anxiolysis was also used, depending on the results of the pre- preoperative assessment. Patients\u2019 sensations/pain during the procedure, details about anesthesia, and the dentist\u2019s considerations were all recorded. Data are expressed as mean \ub1SD. Statistical tests including ANOVA, \u3c72 following Yates correction and linear regression analysis were carried out. A < 0.05 p value was considered significant. Results: Study results showed that the anesthesia was effective and constant in the molar and premolar area. Additional infiltrations of local anesthetics were necessary for vestibular and palatal areas in the anterior oral cavity, respectively, in the GPC and HT groups. The two techniques were equally difficult to carry out in the dentist\u2019s opinion. There were no differences in pain or unpleasant sensations between the two groups, nor were any anesthesia-related complications reported. Conclusion: The GPC approach ensures effective anesthesia in the posterior maxillary region as far as both the dental pulp and the palatal/vestibular mucous membranes are concerned; the HT approach did not guarantee adequate anesthesia of the pterygopalatine branch of the maxillary nerve. These regional anesthesia techniques were characterized by a low incidence of intra and postoperative pain, no noteworthy complications, and high patient satisfaction

    Comparison of energy fluxes at the land surface-atmosphere interface in an Alpine valley as simulated with different models

    No full text
    International audienceWithin the framework of a research project coupling meteorological and hydrological models in mountainous areas a distributed Snow-Soil-Vegetation-Atmosphere Transfer model was developed and applied to simulate the energy fluxes at the land surface ? atmosphere interface in an Alpine valley (Toce Valley - North Italy) during selected flood events in the last decade. Energy fluxes simulated by the distributed energy transfer model were compared with those simulated by a limited area meteorological model for the event of June 1997 and the differences in the spatial and temporal distribution. The Snow/Soil-Vegetation-Atmosphere Transfer model was also applied to simulate the energy fluxes at the land surface-atmosphere interface for a single cell, assumed to be representative of the Siberia site (Toce Valley), where a micro-meteorological station was installed and operated for 2.5 months in autumn 1999. The Siberia site is very close to the Nosere site, where a standard meteorological station was measuring precipitation, air temperature and humidity, global and net radiation and wind speed during the same special observing period. Data recorded by the standard meteorological station were used to force the energy transfer model and simulate the point energy fluxes at the Siberia site, while turbulent fluxes observed at the Siberia site were used to derive the latent heat flux from the energy balance equation. Finally, the hourly evapotranspiration flux computed by this procedure was compared to the evapotranspiration flux simulated by the energy transfer model
    • …
    corecore